Digital Multimeter With Wireless MS8238H
A wireless multimeter for measuring under conditions when remote control of the current values is required.
Presentation
MS8238H is a compact sized multimeter with wireless, it is the ideal solution for professional technician, engineers to keep away from live circuit or electrical panel to prevent dangers while inspecting or measurement. Also, it features with data logging to allows users sharing, data record, and demo graphics with compatible mobile software.
Briefly about the product
MS8238H
1x9V 6F22
148x73.5x50mm
241 g
CE / ETL / RoHS
CAT III 600V
Accessories included
Test Leads
K type thermocouple
Battery and User's manual
Certificates




Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
400mV/4V/40V/400V
600V
600V
0.1mV/0.001V/0.01V/0.1V
1V
1V
±(0.5%+2)
±(0.8%+5)
±(0.8%+5)
AC Voltage
4V/40V/400V/600V
0.001V/0.01V/0.1V/1V
±(1.0%+10)
DC Current
400μA/4000μA/40mA/400mA
10A
10A
0.1μA/1μA/0.01mA/0.1mA
0.01A
0.01A
±(1.0%+10)
±(2.0%+8)
±(2.0%+8)
AC Current
400μA/4000μA/40mA/400mA
10A
10A
0.1μA/1μA/0.01mA/0.1mA
0.01A
0.01A
±(1.2%+5)
±(2.0%+8)
±(2.0%+8)
Resistance
400Ω/4kΩ/40kΩ/400kΩ/4MΩ
40MΩ
40MΩ
0.1Ω/1Ω/0.01kΩ/0.1kΩ/1kΩ
0.01MΩ
0.01MΩ
±(0.8%+3)
±(1.2%+3)
±(1.2%+3)
Temperature
-20°C~1000°C
-4℉~1832℉
-4℉~1832℉
1°C
1℉
1℉
±(2.0%+2)
±(2.0%+4)
±(2.0%+4)
Features
Display
Counts
4000
Autoranging
Auto & Manual
Yes
APO
Auto Power Off
Yes
Diode
Open Voltage
3.2V
Continuity Buzzer
<50Ω
Yes
Data Hold
Yes
NCV
Non-Contact Voltage Detector
Yes
True RMS
For AC Voltage & AC Current
Yes
LBD
Low Battery Display
Yes
Battery Tester
1.5V/9V
Yes
Wireless
APP connection
Yes
Applicability
- The activity of repair groups
- In case of malfunction search
- For Wifi connection
- For the realization of profesional and hobby projects
- For precise and accurate measurement of values

Working specifications
Voltage (V)
Voltage(symbol: V), also called electromotive force, is a quantitative expression of the potential difference in charge between two points in an electrical field.
Current ( I )
An electric current is a flow of electric charge. The common symbol for current is the uppercase letter I. The SI unit for measuring an electric current is the ampere(A), which is the flow of electric charge across a surface at the rate of one coulomb per second. The particles that carry the charge in an electric current are called charge carriers.
Resistance (R)
Resistance is the opposition that a substance offers to the flow of electric current. It is represented by the uppercase letter R. The standard unit of resistance is the ohm(Ω)
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Diode
A diode is a specialized electronic component with two electrodes called the anode and the cathode. Most diodes are made with semiconductor materials such as silicon, germanium, or selenium. The fundamental property of a diode is its tendency to conduct electric current in only one direction. When the cathode is negatively charged relative to the anode at a voltage greater than a certain minimum called forward breakover, then current flows through the diode. If the cathode is positive with respect to the anode, is at the same voltage as the anode, or is negative by an amount less than the forward breakover voltage, then the diode does not conduct current. This is a simplistic view, but is true for diodes operating as rectifiers, switches, and limiters. The forward breakover voltage is approximately six tenths of a volt (0.6 V) for silicon devices, 0.3 V for germanium devices, and 1 V for selenium devices.
Autoranging
Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded. Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded.
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Temperature (°F/°C)
Temperature measurement is done in degrees (°). The unit of measurement adopted by SI is Celsius (° C), but it can also be measured in Fahrenheit (° F). The freezing point of 0 °C = 32 °F and the boiling point 100 °C = 212 °F.
NCV
Non contact voltage, NCV tester is a useful tool for any kind of electrical work - there is no quicker or simpler way to safely check for electrical current in a wire, outlet, switch or an old lamp that has mysteriously stopped working.
TRMS
True Root Mean Square
Wireless
Wireless signal for data transmission or signal analysis.
Battery Test
The battery test is a convenient function for detecting the performance of different types of batteries.
Brochures and instructions