Mastech® Multi-function Digital Counter MS6100. Professional counter with four measured functions for frequency, period, total and self-check.
Product code: MS6100
Warranty: 24 months
Presentation
This is an intelligent multiple function digital counter. Four measurement functions for frequency, period, amounts and self check, the unit has a 10MHz OSC output for the oscilloscope. The instrument can be supplied with two types of voltage 110 VAC and 220 VAC.
Briefly about the product
MS6100
220VAC/110VAC
300x260x74mm
1850 g
RoHS
Accessories included
Power Cord
BNC - BNC - Test Lead 50ohm / 100cm
User's manual
Certificates
RoHS
Range of measurements
Specifications
Range
Resolution
Accuracy
Frequency measurements / channel A
10MHz
(10Hz~10MHz)
100MHz
(10MHz~100MHz)
(10Hz~10MHz)
1,10,100Hz
selectable
10,100,1000Hz
selectable
±1 count ±1x 10-5x frequency (month)
±1 count ±5x10-6x frequency (minute)
Frequency measurements / channel B
1300MHz
(100MHz~1300MHz)
100Hz,1kHz,10kHz
selectable
±1 count ±1x 10-5x frequency (month)
±1 count ±5x10-6x frequency (minute)
Period measurement / channel A (only)
0.1S~0.1μS
(10Hz~10MHz)
0.0μS 0.00μS
0.000μS selectable
±1 count ±1x10-5x frequency (month)
±1 count ±5x10-6x frequency (minute)
Total measurement / channel A (only)
10Hz~10MHz
1 count input
Input characteristics / channel A
MAX Input Voltage: 250V RMS / Impedance: 1MΩ less than 35pF
Input characteristics / channel B
MAX Input Voltage: 3V RMS / Impedance: 50Ω
Features
Display
8 digits, about 10mm high red LED display with decimal point
22000 count
Operating TEMP
0°C ~40°C
Relative Humidity
20%~80%RH (0°C ~40°C)
Reading Hold
Yes
Low Pass Filter
~100kHz, -3dB
~150kHz, -3dB at ATTN condition
Yes
Self-check
Yes
Overrange indication
Yes
OSC. out
10MHz
Yes
Applicability
  • In the laboratory
  • For general oscilloscope testing
Working specifications
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Frequency
Frequency describes the number of crests of a wave that move past a given point in a given unit of time. The most common unit of frequency is the hertz (Hz ), corresponding to one crest per second. The frequency of a wave can be calculated by dividing the speed of the wave by the wavelength.So if the time it takes for a wave to pass is is 1/2 second, the frequency is 2 per second. If it takes 1/100 of an hour, the frequency is 100 per hour.
Self-check
Self-Check Function
Brochures and instructions