Vikiwat LTD - official representative of Mastech for Bulgaria
en
BGN
0

Digital Multimeter With Lan/Phone/Tone Tester MS8236

Multimeter for measuring voltage, AC / DC current, resistance, network cable check and phone check.
Product code: MS8236
Warranty: 24 months
Presentation
The multimeter MS8236 is a modern, electronic measuring device measuring several dimensions. The device is portable and extremely useful for field measurements, home conditions, and is an indispensable assistant to mobile groups of electricians visiting on-site problem areas in industry. The typical multimeter is a combination of a multipurpose voltmeter (AC and DC), and a multipurpose ohmmeter.
Briefly about the product
MS8236
2x9V 6F22
238x43x26mm / 195x92x55mm
470 g
CE / ETL / RoHS
CAT III 600V
Accessories included
Receiver
Test leads
Test Leads
Protective cover
Battery and User's manual
Certificates
CAT III 600V CE certification
Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
200mV/2V/20V/200V/600V
0.1mV/1mV/10mV/100mV/1V
±(0.5%+5)
AC Voltage
200mV/2V/20V/200V/600V
0.1mV/1mV/10mV/100mV/1V
±(0.8%+5)
DC Current
200μA/2000μA/20mA/200mA
2A/10A
0.1μA/1μA/10μA/0.1mA
1mA/10mA
±(1.2%+5)
±(2.0%+10)
AC Current
200μA/2000μA/20mA/200mA
2A/10A
0.1μA/1μA/10μA/0.1mA
1mA/10mA
±(1.5%+5)
±(3.0%+10)
Resistance
200Ω/2kΩ/20kΩ/200kΩ
2MΩ/20MΩ
0.1Ω/1Ω/10Ω/100Ω
1kΩ/10kΩ
±(1.0%+5)
±(1.5%+5)
Features
Display
counts
2000
Autoranging
Auto & Manual
Yes
APO
Auto Power Off
Yes
Diode
Open Voltage
1.7V
Continuity Buzzer
<70Ω
Yes
NCV
Non-contact Voltage Detector
Yes
Reading Hold
Yes
MAX
Maximum measurement
Yes
Network Cable Check
Test for open circuits, shorts, miswires, reversals, split pairs, shield detection.
Main unit and one remote allow one person testing of T568A, T568B, 10Base-T.
Debug mode for detailed fault identification result.
Yes
Phone Check
Identify the state in the working telephone line: Busy, Ringing or Clear
Yes
Tone
Judge the continuity of cables or wires.
Track the cables or wires and diagnose the break point.
Yes
LBD
Low Battery Display
Yes
Display Backlight
Yes
Applicability
  • In an industrial environment
  • For measuring electrical installations
  • Test for open circuits, miswires, split pairs, shield detection
  • Identify the state in the working telephone line: Busy, Ringing or Clear
Working specifications
Current ( I )
An electric current is a flow of electric charge. The common symbol for current is the uppercase letter I. The SI unit for measuring an electric current is the ampere(A), which is the flow of electric charge across a surface at the rate of one coulomb per second. The particles that carry the charge in an electric current are called charge carriers.
Resistance (R)
Resistance is the opposition that a substance offers to the flow of electric current. It is represented by the uppercase letter R. The standard unit of resistance is the ohm(Ω)
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Diode
A diode is a specialized electronic component with two electrodes called the anode and the cathode. Most diodes are made with semiconductor materials such as silicon, germanium, or selenium. The fundamental property of a diode is its tendency to conduct electric current in only one direction. When the cathode is negatively charged relative to the anode at a voltage greater than a certain minimum called forward breakover, then current flows through the diode. If the cathode is positive with respect to the anode, is at the same voltage as the anode, or is negative by an amount less than the forward breakover voltage, then the diode does not conduct current. This is a simplistic view, but is true for diodes operating as rectifiers, switches, and limiters. The forward breakover voltage is approximately six tenths of a volt (0.6 V) for silicon devices, 0.3 V for germanium devices, and 1 V for selenium devices.
Autoranging
Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded. Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded.
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Display Backlight
Rear screen illumination is an important advantage for any device that owns it. Thanks to it, the visibility and legibility of the screen is increased, thus the device is much more subtle and reliable in small ambient light and long-term use.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Maximum Measurement
The "MAX" function shows the highest value reached during the measurement.
NCV
Non contact voltage, NCV tester is a useful tool for any kind of electrical work - there is no quicker or simpler way to safely check for electrical current in a wire, outlet, switch or an old lamp that has mysteriously stopped working.
Network Cable Check
Network Cable Check Function.
Phone Check
Function for Phone Check.
Tone Tester
Function for testing of communication networks with tone signal.
Brochures and instructions
We use cookies to improve your work with our site. By using this site, you agree to our terms and conditions I agree