Universal measuring device with the ability to read environmental parameters. Functions for measuring illumination, noise, temperature and humidity.
Product code: MS8229
Warranty: 24 months
Presentation
Mastech MS8229 is a portable handheld multifunctional digital device used to measure sound, luminosity, humidity, temperature, AC/DC current, electrical resistance, capacitance and frequency. This multipurpose, all-in-one measuring instrument has myriad applications in a plethora of industries and environments. The device has a thermocouple, a condenser microphone and built-in sensors for measuring light and humidity.
Briefly about the product
MS8229
3x1.5V AAA
195x92x55mm
390 g
CE / ETL / RoHS
CAT III 600V
Accessories included
Test Leads
K type thermocouple
Battery and User's manual
Certificates
CAT III 600V CE certification ETL certicfication RoHS
Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
400mV/4V/40V/400V/600V
0.1mV/1mV/10mV/0.1V/1V
±(0.7%+2)
AC Voltage
400mV/4V/40V/400V
600V
0.1mV/1mV/10mV/0.1V
1V
±(0.8%+3)
±(1.0%+3)
DC Current
400μA/4000μA/40mA/400mA
4A/10A
0.1μA/1μA/10μA/0.1mA
1mA/10mA
±(1.2%+3)
±(2.0%+10)
AC Current
400μA/4000μA/40mA/400mA
4A/10A
0.1μA/1μA/10μA/0.1mA
1mA/10mA
±(1.5%+5)
±(3.0%+10)
Resistance
400Ω/4kΩ/40kΩ/400kΩ/4MΩ
40MΩ
0.1μA/1μA/10μA/0.1mA
1mA/10mA
±(1.2%+2)
±(2.0%+5)
Capacitance
40nF/400nF/4μF/40μF/100μF
0.01nF/0.1nF/1nF/10nF/0.1μF
±(3.0%+3)
Frequency
10Hz
100Hz/1000Hz/10kHz
100kHz/200kHz
>200kHz
0.001Hz
0.01Hz/0.1Hz/1Hz
10Hz/0.1kHz
0.1kHz
±(2.0%+5)
±(1.5%+5)
±(2.0%+5)
Reference
Duty Cycle
0.1%~99.9%
0.1%
±(3.0%)
K-Type Temperature
-20℃~0℃
1℃~400℃
401℃ ~1000℃
-4℉~32℉
33℉~752℉
753℉~1832℉
1℃
1℃
1℃
1℉
1℉
1℉
±(5.0%+3)
±(1.0%+2)
±(2.0%)
±(5.0%+6)
±(1.0%+4)
±(2.0%)
Environment temperature
0℃~40℃
32℉~104℉
0.1℃
0.1℉
±(2.0℃)
±(4.0℉)
Relative Humidity
20%~95%
0.10%
±(5.0%)
Sound Level
40dB~100dB
0.1dB
±(3.5%)
Luminosity
4000Lux/40000Lux
1Lux/10Lux
±(5.0%+10)
Features
Display
Counts
4000
Autoranging
Auto & Manual
Yes
APO
Auto Power Off
Yes
Diode
Open Voltage
1.5V
Continuity Buzzer
<50±20Ω
Yes
°C/°F Selection
Yes
Data Hold
Yes
LBD
Low Battery Display
Yes
Display Backlight
Yes
Applicability
  • To measure noise in factories, schools, offices, acoustics checking in studios and scenes
  • Indispensable assistant in the construction of sound systems
  • For measuring illumination in work rooms
  • Temperature reading by thermocouple type K
  • Measurement of air humidity
  • For measuring values in electrical installations
Working specifications
Resistance (R)
Resistance is the opposition that a substance offers to the flow of electric current. It is represented by the uppercase letter R. The standard unit of resistance is the ohm(Ω)
Capacitance ( C )
Capacitance is the ability of a component or circuit to collect and store energy in the form of an electrical charge. The SI unit of capacitance is the farad (symbol: F), named after the English physicist Michael Faraday. A farad capacitor, when charged with 1 coulomb of electrical charge, has a potential difference of 1 volt between its plates.
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Diode
A diode is a specialized electronic component with two electrodes called the anode and the cathode. Most diodes are made with semiconductor materials such as silicon, germanium, or selenium. The fundamental property of a diode is its tendency to conduct electric current in only one direction. When the cathode is negatively charged relative to the anode at a voltage greater than a certain minimum called forward breakover, then current flows through the diode. If the cathode is positive with respect to the anode, is at the same voltage as the anode, or is negative by an amount less than the forward breakover voltage, then the diode does not conduct current. This is a simplistic view, but is true for diodes operating as rectifiers, switches, and limiters. The forward breakover voltage is approximately six tenths of a volt (0.6 V) for silicon devices, 0.3 V for germanium devices, and 1 V for selenium devices.
Autoranging
Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded. Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded.
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Display Backlight
Rear screen illumination is an important advantage for any device that owns it. Thanks to it, the visibility and legibility of the screen is increased, thus the device is much more subtle and reliable in small ambient light and long-term use.
Duty Cycle
Duty cycle is the proportion of time during which a component, device, or system is operated. The duty cycle can be expressed as a ratio or as a percentage. Suppose a disk drive operates for 1 second, then is shut off for 99 seconds, then is run for 1 second again, and so on. The drive runs for one out of 100 seconds or 1/100 of the time, and its duty cycle is therefore 1/100, or 1 percent.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Temperature (°F/°C)
Temperature measurement is done in degrees (°). The unit of measurement adopted by SI is Celsius (° C), but it can also be measured in Fahrenheit (° F). The freezing point of 0 °C = 32 °F and the boiling point 100 °C = 212 °F.
Average value
AVG function shows the average of the measurements.
illuminance
Illumination - The device uses a built-in sensor.
Sound measuring
The meter reads noise in factories, schools, offices, airports, and more. It can also be used to check the acoustics of studios, scenes and sound system installations.
Brochures and instructions