Digital Multimeter MY78
Multimeter with the ability to measure voltage, AC / DC current, resistance, capacitance, and hFE of transistors. Possibility to include additional ampere clamps.
Presentation
The compact multimeter MY78 is a digital, multifunctional measuring device that has the ability to measure various electrical quantities: DC and AC voltage, DC and AC, resistance, charging capacity and measurement of hFE transistors. The device has an audible alarm during a continuity test. Possibility to connect current clamps MS3300 and MS3302 (not included in the set) for non-contact current measurement.
Briefly about the product
MY78
1x9V 6F22
189x91x31.5mm
420 g
CE / ETL / RoHS
CATIII 600V
Accessories included
Test Leads
Multi-Function Socket
Battery and User's manual
Certificates




Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
400mV/4V/40V/400V
600V
600V
0.1mV/1mV/10mV/0.1V
0.1V/1V
0.1V/1V
±(0.7%+2)
±(0.8%+2)
±(0.8%+2)
AC Voltage
400 mV
4V/40V/400V
600V
4V/40V/400V
600V
0.1mV
1mV/10mV/0.1V
0.1V/1V
1mV/10mV/0.1V
0.1V/1V
±(3.0%+3)
±(0.8%+3)
±(1.2%+3)
±(0.8%+3)
±(1.2%+3)
DC Current
400μA/4000μA/40mA/400mA
10Α
10Α
0.1μA/1μA/10μA/0.1mA
1mA/10mA
1mA/10mA
±(1.2%+3)
±(2.0%+5)
±(2.0%+5)
AC Current
400μA/4000μA/40mA/400mA
10Α
10Α
0.1μA/1μA/10μA/0.1mA
1mA/10mA
1mA/10mA
±(1.5%+5)
±(3.0%+7)
±(3.0%+7)
Resistance
400Ω/4kΩ/40kΩ/400kΩ/4ΜΩ
40ΜΩ
40ΜΩ
0.1Ω/1Ω/10Ω/0.1kΩ/1kΩ
0.01MΩ
0.01MΩ
±(1.2%+2)
±(2.0%+5)
±(2.0%+5)
Capacitance
4nF
40nF/400nF/4μF/40μF/200μF
40nF/400nF/4μF/40μF/200μF
1pF
0.01nF/0.1nF/1nF/10nF/0.1μF
0.01nF/0.1nF/1nF/10nF/0.1μF
±(4.0%+25)
±(4.0%+15)
±(4.0%+15)
Frequency
10Hz/100Hz/1kHz
10kHz/100kHz/200kHz
>200kHz
10kHz/100kHz/200kHz
>200kHz
0.01Hz/0.01Hz/0.1Hz
1Hz/10Hz/0.1kHz
0.1kHz
1Hz/10Hz/0.1kHz
0.1kHz
±(2.0%+5)
±(2.0%+5)
Reference
±(2.0%+5)
Reference
DC Current (for Clamp Meter)
40A
400A
400A
1A/1mV
1A/1mV
1A/1mV
±(0.8%+3)
±(0.8%+3)
±(0.8%+3)
AC Current (for Clamp Meter)
40A
400A
400A
1A/1mV
1A/1mV
1A/1mV
±(1.0%+3)
±(1.0%+3)
±(1.0%+3)
Duty Cycle
5% ~ 95%
0.1%
±(2.0%+2)
Features
Display
Counts
4000
Autoranging
Auto and manual
Yes
APO
Auto Power Off
Yes
REL
Relative Measurement
Yes
Transistor hFE
0~1000
Yes
Diode
Open Voltage
1.5V
Continuity Buzzer
<50Ω±20Ω
Yes
Data Hold
Yes
LBD
Low Battery Display
Yes
Applicability
- In an industrial environment
- For measuring electrical installations
- Identify the state in the working telephone line: Busy, Ringing or Clear
- Test for open circuits, miswires, shield detection
Working specifications
Capacitance ( C )
Capacitance is the ability of a component or circuit to collect and store energy in the form of an electrical charge. The SI unit of capacitance is the farad (symbol: F), named after the English physicist Michael Faraday. A farad capacitor, when charged with 1 coulomb of electrical charge, has a potential difference of 1 volt between its plates.
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Diode
A diode is a specialized electronic component with two electrodes called the anode and the cathode. Most diodes are made with semiconductor materials such as silicon, germanium, or selenium. The fundamental property of a diode is its tendency to conduct electric current in only one direction. When the cathode is negatively charged relative to the anode at a voltage greater than a certain minimum called forward breakover, then current flows through the diode. If the cathode is positive with respect to the anode, is at the same voltage as the anode, or is negative by an amount less than the forward breakover voltage, then the diode does not conduct current. This is a simplistic view, but is true for diodes operating as rectifiers, switches, and limiters. The forward breakover voltage is approximately six tenths of a volt (0.6 V) for silicon devices, 0.3 V for germanium devices, and 1 V for selenium devices.
Autoranging
Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded. Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded.
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Duty Cycle
Duty cycle is the proportion of time during which a component, device, or system is operated. The duty cycle can be expressed as a ratio or as a percentage. Suppose a disk drive operates for 1 second, then is shut off for 99 seconds, then is run for 1 second again, and so on. The drive runs for one out of 100 seconds or 1/100 of the time, and its duty cycle is therefore 1/100, or 1 percent.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Ralative Measurement
Function to display a relative measurement value.
Transistor hFE
Transistor-check function. hFE of a transistor is the current gain or amplification factor of a transistor.
Brochures and instructions
Accessories