Vikiwat LTD - official representative of Mastech for Bulgaria
en
BGN
0

Digital Multimeter MY70

Multimeter capable of measuring voltage, AC / DC current and resistance, and transistor hFE.
Product code: MY70
Warranty: 24 months
Presentation
The MY70 compact multimeter is a digital, multifunctional meter that has the ability to measure different electrical quantities: DC and AC and resistance. The device has an audible alarm for continuity test.
Briefly about the product
MY70
1x9V 6F22
188x93x50mm
380 g
CE/ ETL / RoHS
CAT lll 600V
Accessories included
Test Leads
Multi-Function Socket
Battery and User's manual
Certificates
CAT III 600V CE certification ETL certicfication RoHS
Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
200mV/2V/20V/200V
600V
0.1mV/1mV/10mV/0.1V
1V
±(0.5%+2)
±(0.8%+2)
AC Voltage
200mV
2V/20V/200V
600V
0.1mV
1mV/10mV/0.1V
1V
±(1.2%+3)
±(0.8%+3)
±(1.2%+3)
DC Current
20μA
200μA
2mA
20mA
200mA
10A
0.01μA
0.1μA
1μA
10μA
0.1mA
0.01A
±(2.0%+5)
±(0.8%+1)
±(0.8%+1)
±(0.8%+1)
±(1.5%+1)
±(2.0%+5)
AC Current
20μA
200μA
2mA
20mA
200mA
10A
0.01μA
0.1μA
1μA
10μA
0.1mA
0.01A
±(2.0%+5)
±(1.0%+5)
±(1.0%+5)
±(1.0%+5)
±(1.8%+5)
±(3.0%+7)
Resistance
200Ω
2kΩ/20kΩ/200kΩ/2MΩ
20MΩ
200MΩ
0.1Ω
1Ω/10Ω/0.1kΩ/1kΩ
10kΩ
0.1MΩ
±(0.8%+3)
±(0.8%+2)
±(1.0%+2)
±(6.0%+10)
Features
Display
Counts
Yes
APO
Auto Power Off
Yes
Transistor hFE
0~1000
Yes
Diode
Open Voltage
3.0V
Continuity Buzzer
<50Ω
Data Hold
Yes
LBD
Low Battery Display
Yes
Applicability
  • In an industrial environment
  • For measuring electrical installations
  • Identify the state in the working telephone line: Busy, Ringing or Clear
  • Test for open circuits, miswires, shield detection
Working specifications
Current ( I )
An electric current is a flow of electric charge. The common symbol for current is the uppercase letter I. The SI unit for measuring an electric current is the ampere(A), which is the flow of electric charge across a surface at the rate of one coulomb per second. The particles that carry the charge in an electric current are called charge carriers.
Resistance (R)
Resistance is the opposition that a substance offers to the flow of electric current. It is represented by the uppercase letter R. The standard unit of resistance is the ohm(Ω)
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Diode
A diode is a specialized electronic component with two electrodes called the anode and the cathode. Most diodes are made with semiconductor materials such as silicon, germanium, or selenium. The fundamental property of a diode is its tendency to conduct electric current in only one direction. When the cathode is negatively charged relative to the anode at a voltage greater than a certain minimum called forward breakover, then current flows through the diode. If the cathode is positive with respect to the anode, is at the same voltage as the anode, or is negative by an amount less than the forward breakover voltage, then the diode does not conduct current. This is a simplistic view, but is true for diodes operating as rectifiers, switches, and limiters. The forward breakover voltage is approximately six tenths of a volt (0.6 V) for silicon devices, 0.3 V for germanium devices, and 1 V for selenium devices.
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Transistor hFE
Transistor-check function. hFE of a transistor is the current gain or amplification factor of a transistor.
Brochures and instructions
We use cookies to improve your work with our site. By using this site, you agree to our terms and conditions I agree