Vikiwat LTD - official representative of Mastech for Bulgaria
en
BGN
0

Digital Multimeter MS8238C

Multimeter capable of measuring voltage, AC / DC current, resistance and temperature, as well as battery test function - 1.5V, 9V and 12V.
Product code: MS8238C
Warranty: 24 months
Presentation
MS8238C is a digital, multifunctional measuring instrument that has the ability to measure different electrical quantities: AC / DC voltage, AC / DC current, resistance and temperature. The device has an Battery Test 1.5V / 9V / 12V.
Briefly about the product
MS8238C
1x9V 6F22
148x73.5x50mm
232 g
CE / ETL / RoHS
CAT III 600V
Accessories included
Test Leads
K type thermocouple
Battery and User's manual
Certificates
CAT III 600V CE certification ETL certicfication RoHS
Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
200mV/2V/20V/200V
600V
0.1mV/1mV/10mV/0.1V
1V
±(0.5%+3)
±(0.8%+3)
AC Voltage
2V/20V/200V
600V
1mV/10mV/0.1V
1V
±(0.5%+5)
±(1.0%+5)
DC Current
200μA/2000μA/20mA
200mA
10A
0.1μA/1μA/0.01mA
0.1mA
10mA
±(0.8%+3)
±(0.8%+3)
±(1.0%+10)
AC Current
200μA/2000μA/20mA
200mA
10A
0.1μA/1μA/0.01mA
0.1mA
10mA
±(1.0%+3)
±(1.2%+3)
±(1.5%+10)
Resistance
200Ω/2kΩ/20kΩ
200kΩ/2MΩ
20MΩ
0.1Ω/1Ω/10Ω
0.1kΩ/1kΩ
0.01MΩ
±(0.8%+4)
±(0.8%+4)
±(1.0%+4)
Temperature
-20℃~750℃
-4℉~1382℉
1℃
1℉
±(2.0%+2)
±(2.0%+4)
Features
Display
Counts
2000
Autoranging
Yes
APO
Auto Power Off
Yes
Diode
Open Voltage
1.5V
Continuity Buzzer
<50±20Ω
Data Hold
Yes
NCV
Non-contact voltage detection
Yes
LBD
Low Battery Display
Yes
Battery Tester
1.5V/9V/12V
Applicability
  • In an industrial environment
  • For measuring electrical installations
  • Suitable for mobile, repair teams
Working specifications
Voltage (V)
Voltage(symbol: V), also called electromotive force, is a quantitative expression of the potential difference in charge between two points in an electrical field.
Current ( I )
An electric current is a flow of electric charge. The common symbol for current is the uppercase letter I. The SI unit for measuring an electric current is the ampere(A), which is the flow of electric charge across a surface at the rate of one coulomb per second. The particles that carry the charge in an electric current are called charge carriers.
Resistance (R)
Resistance is the opposition that a substance offers to the flow of electric current. It is represented by the uppercase letter R. The standard unit of resistance is the ohm(Ω)
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Diode
A diode is a specialized electronic component with two electrodes called the anode and the cathode. Most diodes are made with semiconductor materials such as silicon, germanium, or selenium. The fundamental property of a diode is its tendency to conduct electric current in only one direction. When the cathode is negatively charged relative to the anode at a voltage greater than a certain minimum called forward breakover, then current flows through the diode. If the cathode is positive with respect to the anode, is at the same voltage as the anode, or is negative by an amount less than the forward breakover voltage, then the diode does not conduct current. This is a simplistic view, but is true for diodes operating as rectifiers, switches, and limiters. The forward breakover voltage is approximately six tenths of a volt (0.6 V) for silicon devices, 0.3 V for germanium devices, and 1 V for selenium devices.
Autoranging
Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded. Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded.
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Temperature (°F/°C)
Temperature measurement is done in degrees (°). The unit of measurement adopted by SI is Celsius (° C), but it can also be measured in Fahrenheit (° F). The freezing point of 0 °C = 32 °F and the boiling point 100 °C = 212 °F.
NCV
Non contact voltage, NCV tester is a useful tool for any kind of electrical work - there is no quicker or simpler way to safely check for electrical current in a wire, outlet, switch or an old lamp that has mysteriously stopped working.
Battery Test
The battery test is a convenient function for detecting the performance of different types of batteries.