Digital AC Clamp Meter M266
Digital Clamps Meter for contactless AC measurement, as well as DC and AC measurement, resistance, circuit continuity and insulation test.
Presentation
The M266 digital amps are designed for contactless measurement of AC values, as well as DC and AC voltage, resistance, circuit continuity and insulation tests.
Briefly about the product
M266
1x9V 6F22
235x96x46mm
268 g
CE / ETL / RoHS
CAT II 1000V / CAT III 600V
Accessories included
Test Leads
Carry bag
Battery and User's manual
Certificates
Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
1000V
1V
±(0.8%+3)
AC Voltage
750V
1V
±(1.2%+5)
AC Current
200A
1000A
1000A
0.1A
1A
1A
±(2.5%+5)
±(3.0%+10)
±(3.0%+10)
Resistance
200Ω
20kΩ
20kΩ
0.1Ω
10Ω
10Ω
±(1.0%+5)
±(1.0%+8)
±(1.0%+8)
Insulation Test
20MΩ
2000MΩ (Note<500MΩ)
2000MΩ (Note>500MΩ)
2000MΩ (Note<500MΩ)
2000MΩ (Note>500MΩ)
10kΩ
1MΩ
1MΩ
1MΩ
1MΩ
±(2.0%+2)
±(4.0%+2)
±(5.0%+2)
±(4.0%+2)
±(5.0%+2)
Features
Display
Counts
2000
Jaw Opening
Ф50mm
Continuity Buzzer
<100Ω
Data Hold
Yes
LBD
Low Battery Display
Yes
Applicability
- To measure the current flowing with working loads
- Suitable for mobile repair teams
- For realization of hobby projects
Working specifications
Voltage (V)
Voltage(symbol: V), also called electromotive force, is a quantitative expression of the potential difference in charge between two points in an electrical field.
AC Current
An electric current is a flow of electric charge. The common symbol for current is the uppercase letter I. The SI unit for measuring an electric current is the ampere(A), which is the flow of electric charge across a surface at the rate of one coulomb per second. The particles that carry the charge in an electric current are called charge carriers.
Resistance (R)
Resistance is the opposition that a substance offers to the flow of electric current. It is represented by the uppercase letter R. The standard unit of resistance is the ohm(Ω)
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.