Circuit Analyzer MS5908C

Circuit analyzer for testing of electrical installations. For earth voltage measurement,RCD testing, voltage drops and more.
Product code: MS5908C
Warranty: 24 months
Presentation
This circuit analyzer is a special test device designed for AC low-voltage distribution line quick fault location. With simple operation, accurate measurement and other features, it can detect multiple problems on a line, such as causing to electric shock, electrical fire, abnormal operation of equipment, etc
Briefly about the product
MS5908C
6x1.5V AAA
194x78x37mm
254 g
CE / ETL / RoHS
CAT III 300V
Accessories included
Power Cord
Carry bag
Battery and User's manual
Certificates
CAT III 300V CE certification ETL certicfication RoHS
Range of measurements
Specifications
Range
Resolution
Accuracy
Line Voltage
85.0~265.0V
0.1V
±(1.0%+2)
Peak Line Voltage
120.0~375.0V
0.1V
±(1.0%+2)
Voltage With Loading Equipments
10.0~265.0V
0.1V
±(2.5%+2)
Neutral-Ground Voltage
0.0~10.0V
0.1V
±(2.5%+2)
RCD Trip Time
1ms~6.5S
1mS
±(1.0%+2)
RCD Trip Current
30mA~37mA
0.1mA
±(1.0%+2)
GFCI Trip Time
1ms~6.5S
1mS
±(1.0%+2)
GFCI Trip Current
6mA~9mA
0.1mA
±(1.0%+2)
Voltage Drop
0.1~99.9%
0.1%
±(2.5%+2)
Voltage Drop Load Current
5/8/10A
Impedance-live and Neutral & Earth
0.00~3.00Ω
>3.00Ω
0.01Ω
0.01Ω
±(2.5%+2)
No ensure
Line Frequency
45.0~65.0Hz
0.1Hz
±(1.0%+2)
Features
APO
Auto Power Off
Yes
Data Hold
Yes
LBD
Low Battery Display
Yes
Applicability
  • In installers
  • In case of grounding of electrical installations
  • For safety installing electrical installations and equipment in home and industrial environment
  • In case of grounding of electrical installations
Working specifications
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Display Backlight
Rear screen illumination is an important advantage for any device that owns it. Thanks to it, the visibility and legibility of the screen is increased, thus the device is much more subtle and reliable in small ambient light and long-term use.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.
Frequency
Frequency describes the number of crests of a wave that move past a given point in a given unit of time. The most common unit of frequency is the hertz (Hz ), corresponding to one crest per second. The frequency of a wave can be calculated by dividing the speed of the wave by the wavelength.So if the time it takes for a wave to pass is is 1/2 second, the frequency is 2 per second. If it takes 1/100 of an hour, the frequency is 100 per hour.
Ground Fault Circuit Interrupter
Ground Fault Circuit Interrupter is a device that shuts off an electric power circuit when it detects that current is flowing along an unintended path, such as through water or a person. It is used to reduce the risk of electric shock, which can cause the heart to stop or cause burns. They can also prevent some fires, like when a live wire touches a metal conduit. Trip Current :4~6mA (for standard) Trip Time :25ms (for standard)
Residual Current Device
Residual Current Device is a device that shuts off an electric power circuit when it detects that current is flowing along an unintended path, such as through water or a person. It is used to reduce the risk of electric shock, which can cause the heart to stop or cause burns. They can also prevent some fires, like when a live wire touches a metal conduit. Trip Current :5~30mA (for standard) Trip Time :25~40ms (for standard)