Digital Multimeter MS8333A
The MS8333A digital multimeter measures electrical quantities such as AC / DC voltage, AC / DC current, resistance, capacitance, frequency, battery test, and duty cycle.
Presentation
The device is portable and extremely useful for field, home and mobile measurements by field technicians visiting on-site problem areas in the industry. It measures electrical quantities such as AC / DC current and voltage, resistance, capacitance, frequency, and the battery charge and test.
Briefly about the product
MS8333A
2x1.5V AAA
122x62x44mm
186 g
CE / ETL / RoHS
CAT III 600V
Accessories included
Battery and User's manual
Certificates
Range of measurements
Specifications
Range
Resolution
Accuracy
DC Voltage
600mV/6V/60V/600V
0.1mV/0.001V/0.01V/0.1V
±(0.5%+3)
AC Voltage
6V/60V/600V
0.001V/0.01V/0.1V
±(1.0%+3)
DC Current
600µA/6000µA/60mA/600mA
0.1µA/1µA/0.01mA/0.1mA
±(1.0%+5)
AC Current
600µA/6000µA/60mA/600mA
0.1µA/1µA/0.01mA/0.1mA
±(1.8%+3)
Resistance
600Ω/6kΩ/60kΩ/600kΩ/6MΩ
60MΩ
60MΩ
0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ/0.001MΩ
0.01MΩ
0.01MΩ
±(0.7%+3)
±(2.0%+3)
±(2.0%+3)
Capacitance
6nF/60nF/600nF/6uF/60uF/600uF
0.001nF/0.01nF/0.1nF/1nF/10nF/100nF
±(3.0%+8)
Frequency
10Hz/100Hz/1000Hz/10kHz
0.001Hz/0.01Hz/0.1Hz/1Hz
±(1.5% +15)
Duty Cycle
0.5%~99.9%
0.1%
±(2.0%+5)
Features
Display
Counts
6000
Autoranging
Auto
Yes
APO
Auto Power Off
Yes
Diode
Open Voltage
4V
Continuity Buzzer
<50Ω±20Ω
Yes
Data Hold
Yes
NCV
Non-Contact Voltage Detector
Yes
True RMS
Yes
LBD
Low Battery Display
Yes
Battery Tester
1.5V
Yes
Display Backlight
Yes
Applicability
- For fast and accurate measurements
- In an industrial environment
- For measuring electrical installations
- For battery test
Working specifications
Voltage (V)
Voltage(symbol: V), also called electromotive force, is a quantitative expression of the potential difference in charge between two points in an electrical field.
Current ( I )
An electric current is a flow of electric charge. The common symbol for current is the uppercase letter I. The SI unit for measuring an electric current is the ampere(A), which is the flow of electric charge across a surface at the rate of one coulomb per second. The particles that carry the charge in an electric current are called charge carriers.
Resistance (R)
Resistance is the opposition that a substance offers to the flow of electric current. It is represented by the uppercase letter R. The standard unit of resistance is the ohm(Ω)
Capacitance ( C )
Capacitance is the ability of a component or circuit to collect and store energy in the form of an electrical charge. The SI unit of capacitance is the farad (symbol: F), named after the English physicist Michael Faraday. A farad capacitor, when charged with 1 coulomb of electrical charge, has a potential difference of 1 volt between its plates.
Buzzer
In electronics, a continuity test is the checking of an electric circuit to see if current flows . A continuity test is performed by placing a small voltage across the chosen path. If electron flow is inhibited by broken conductors, damaged components, or excessive resistance, the circuit is "open".
Diode
A diode is a specialized electronic component with two electrodes called the anode and the cathode. Most diodes are made with semiconductor materials such as silicon, germanium, or selenium. The fundamental property of a diode is its tendency to conduct electric current in only one direction. When the cathode is negatively charged relative to the anode at a voltage greater than a certain minimum called forward breakover, then current flows through the diode. If the cathode is positive with respect to the anode, is at the same voltage as the anode, or is negative by an amount less than the forward breakover voltage, then the diode does not conduct current. This is a simplistic view, but is true for diodes operating as rectifiers, switches, and limiters. The forward breakover voltage is approximately six tenths of a volt (0.6 V) for silicon devices, 0.3 V for germanium devices, and 1 V for selenium devices.
Autoranging
Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded. Automatic switching of a multirange meter from its lowest to the next higher range, with the switching process repeated until a range is reached for which the full-scale value is not exceeded.
Auto Power Off
Auto Power Off function shutting down the device after a certain inactivity time.
Display Backlight
Rear screen illumination is an important advantage for any device that owns it. Thanks to it, the visibility and legibility of the screen is increased, thus the device is much more subtle and reliable in small ambient light and long-term use.
Duty Cycle
Duty cycle is the proportion of time during which a component, device, or system is operated. The duty cycle can be expressed as a ratio or as a percentage. Suppose a disk drive operates for 1 second, then is shut off for 99 seconds, then is run for 1 second again, and so on. The drive runs for one out of 100 seconds or 1/100 of the time, and its duty cycle is therefore 1/100, or 1 percent.
Low Battery
The indication for low battery level is a useful feature and alert the user when needed battery unit to be changed. So you will still have a functioning device for use.
Data Hold
Data hold function is useful when measurements occur. So when pressing the "HOLD" button you will hold the display information.